Symrise
GmbH & Co. KG
NEWS & EVENTS: Press
Releases | Industry
Events | Application Photos
Symrise
Inc., Teterboro, NJ, a leading creator of flavors,
fragrances, aroma chemicals, and specialty cosmetic
ingredients selected Franek Technologies, Inc., leader
in certified Category III-3 Laboratory Battery Backup
Power Protection Systems (LPS/UPS), to safeguard its
$600,000 investment in analytical research
instrumentation at its Flavor Research Analysis
Laboratory in Totowa, New Jersey.
Symrise
GmbH & Co. KG (Symrise) is one of the world's
leading international manufacturers of flavors,
fragrances, cosmetic ingredients and aroma chemicals.
With a market share of 11.3% for fragrances and flavors
worldwide, Symrise holds a strong 4th place in the
industry's top ten. Symrise employs approx. 5,600 people
across the globe and has subsidiaries representing the
company on all five continents. Sales exceed €1.25
billion ($1.55 billion US).
|

|
|

|
|
Agilent 6890 Plus GC (FID) and 5973
MSD with 208 V service (5973 GC-MSD)
Franek Technologies LPS Catalog Number
FT1-5973CS2-AG – extended run time
Instrument Description: The Agilent 5973 GC-MSD is
highly sensitive benchtop mass spectrometer
combining the Agilent 6890 Plus Fast Oven, Gerstel
Autosampler, ODP Sniff Port, and Agilent 5973 with
an inert Mass Selective Detector for analysis of
active compounds such as pesticides, drugs of
abuse and chemical warfare agents.
While pesticides improve crop yields and help
alleviate food shortages, many of the chemicals
used have deleterious effects on health.
To ensure safe foods, in excess of 700
pesticides are regulated worldwide.
Many laboratories qualify samples using a
GC and a pesticide-screening program identifying
each pesticide, or other organic contaminant,
by its retention time.
Following screening, samples containing
pesticides that exceed regulated levels are
further analyzed for confirmation on a GC equipped
with a Mass Selective Detector (MSD).
Symrise utilizes these instruments to
screen for contaminants in its Flavor Analysis
Laboratory.
Application: Active compound screening such as
pesticides, contaminants, drugs of abuse and
chemical warfare agents.
Gas Chromatography and Mass Spectroscopy (GC, MS and GC-MS)
|
|
Dionex ASE 200 Automated Solvent Extractor
Franek Technologies LPS Catalog Number
FT1-ASE200-DXEX – extended run time
Instrument Description:
The Dionex ASE® 200
Accelerated Solvent Extractor provides rapid and
automated extraction of target analytes from a
broad range of solid and semi-solid samples.
It can extract up to 24 samples,
unattended, and deliver filtered extracts, ready
for cleanup and analysis.
Symrise
utilizes this instrument to screen for
contaminants in its Flavor Analysis Laboratory.
Application:
Active compound screening such as pesticides,
contaminants, drugs of abuse and chemical warfare
agents
High Performance Liquid Chromatography, Gas
Chromatography, and Mass Spectroscopy (HPLC, GC,
MS, GC-MS, and LC-MS)
|
|
|
|
|
|

|
|

|
|
Agilent 6890N Network GC System - Fast Oven Option
Franek Technologies LPS Catalog Number
FT1-6890GCF-AG – extended run time
Instrument Description: The
Agilent 6890N Network GC Systems with the Fast
Oven Option and software make it possible to
analyze samples with high levels of matrix
contamination.
Tools
such as mass spectral deconvolution, reliable and
inert effluent splitters, and column backflushing
capabilities can be combined to produce large
timesavings for a complete analysis.
By accelerating the chromatographic run,
post-run bakeout, and data interpretation steps,
analysis times can be shortened by at least
three-fold versus conventional methods.
These techniques are especially useful in
analyses with high levels of matrix background
clutter, such as the inspection of the food supply
for contaminants.
In addition to monitoring for pesticide
residues and trace element contamination, the
threat of terrorism has recently raised concerns
over deliberate contamination of food with other
toxic materials.
The Agilent 6890N with the Fast Oven option
is a GC/MS system for the rapid screening of
foodstuffs for chemical contaminants with a
special emphasis on pesticides, organophosphorus,
and organosulfur compounds.
Symrise utilizes this instrument to screen
for contaminants in its Flavor Analysis
Laboratory.
Application: Active compound screening such as
pesticides, contaminants, drugs of abuse and
chemical warfare agents
Gas Chromatography and Mass Spectroscopy (GC, MS
and GC-MS)
|
|
Overview of Agilent 6890 Plus GC (FID) and 5973
Franek Technologies LPS Catalog Number
FT1-5973CS2-AG – extended run time cabinet
Instrument Description: The Agilent 5973 GC-MSD is
a highly sensitive benchtop mass spectrometer
combining the Agilent 6890 Plus Fast Oven, Gerstel
Autosampler, ODP Sniff Port, and Agilent 5973 with
and inert Mass Selective Detector for analysis of
active compounds such as pesticides, drugs of
abuse and chemical warfare agents.
Symrise utilizes this instrument to screen
for contaminants in its Flavor Analysis
Laboratory.
Application: Active compound screening such as
pesticides, contaminants, drugs of abuse and
chemical warfare agents.
Gas Chromatography and Mass Spectroscopy (GC, MS
and GC-MS)
|
|
|
|
|
|

|
|

|
|
Detailed view of
Certified Category III-3 Instrumentation Grade LPS
– extended run time
On left: Franek Technologies LPS Catalog Number
FT1-6890GC-AEX
On right: Franek Technologies LPS Catalog Number
FT1-5973CS2-AG
Instrument Description: The Agilent 5973 GC-MSD
with an inert Mass Selective Detector is a highly
sensitive benchtop mass spectrometer including the Agilent 6890 Plus Fast Oven.
These
instruments are utilized for analysis of active
compounds such as pesticides, drugs of abuse and
chemical warfare agents.
Application: Active compound screening such as
pesticides, contaminants, drugs of abuse and
chemical warfare agents.
Gas Chromatography and Mass Spectroscopy (GC, MS
and GC-MS)
|
|
The umbilical Power Distribution Unit (PDU) for the Agilent
6890 Plus GC and 5973 MSD
Instrument Description: The Agilent 5973 GC-MSD
with an inert Mass Selective Detector is a highly
sensitive benchtop mass spectrometer including the
Agilent 6890 Plus Fast Oven.
These instruments are utilized for analysis
of active compounds such as pesticides, drugs of
abuse and chemical warfare agents
Application: Active compound screening such as
pesticides, contaminants, trace elements, drugs of
abuse and chemical warfare agents
Gas Chromatography and Mass Spectroscopy (GC, MS
and GC-MS)
|
|
|
|
|
|

|
|

|
|
Close-up view of Agilent 6890 Plus GC and 5973 MSD power
protection LPS units
Instrument Description: The Agilent 5973 GC-MSD
with an inert Mass Selective Detector is a highly
sensitive benchtop mass spectrometer
including the Agilent 6890 Plus Fast Oven.
These instruments are utilized for analysis
of active compounds such as pesticides, drugs of
abuse and chemical warfare agents
Symrise utilizes these instruments to
screen for contaminants in its Flavor Analysis
Laboratory.
Application: Active compound screening such as
pesticides, contaminants, trace elements, drugs of
abuse and chemical warfare agents
Gas Chromatography and Mass Spectroscopy (GC, MS
and GC-MS)
|
|
View of Agilent 6890 Plus GC and Atomic Emission Detector (AED)
On left: Franek Technologies LPS Catalog Number
FT1-6890GC-AED – extended run time cabinet
Instrument Description: The Agilent 6890N
Networked GC-AED with an Atomic Emission Detector
is a highly sensitive benchtop mass spectrometer utilizing
another detection technique
for the analysis of active compounds such
as pesticides, drugs of abuse and chemical warfare
agents. Symrise
utilizes this instrument to screen for
contaminants in its Flavor Analysis Laboratory.
Application: Active compound screening such as
pesticides, contaminants, trace elements, drugs of
abuse and chemical warfare agents
Gas Chromatography and Mass Spectroscopy (GC, MS
and GC-MS)
|
|
|
|
|
|

|
|
|
|
Agilent 6890 Plus GC Flame Ionization Detector (FID) and
Atomic Emission Detector (GC-AED)
Franek Technologies LPS Catalog Number
FT1-6890GCAED-A – extended run time cabinet
Instrument Description: The Agilent 6890N
Networked GC-AED with an Atomic Emission Detector
is a highly sensitive benchtop mass spectrometer
utilizing another detection technique
for the analysis of active compounds such
as pesticides, drugs of abuse and chemical warfare
agents. Symrise
utilizes this instrument to screen for
contaminants in its Flavor Analysis Laboratory.
Application: Active compound screening such as
pesticides, contaminants, trace elements, drugs of
abuse and chemical warfare agents
Gas Chromatography and Mass Spectroscopy (GC, MS
and GC-MS)
|
|
|
For
high-resolution images please contact Jeanna Sanchez,
JCS Public Relations at (760) 295-4166 or via E-mail: jeanna@jcspublicrelations.com
All
photos courtesy of Symrise GmbH & Co.. |